UAH Ceilometer Data Format 18:55:41 08/20/2001 40 01800 03300 ///// 00000800 100 N 99 +36 110 0 +4 203 LF7LN1 180 000 525 490 400 335 314 290 276 272 256 232 213 202 187 187 178 160 016 164 160 145 131 140 106 111 81 76 74 62 59 63 63 29 16 032 42 -1 18 13 14 -11 -6 26 17 9 -13 -26 -5 -1 -10 -9 048 1 -11 -4 -3 6 -20 -8 24 7 18 -12 7 -19 5 20 3 064 30 -24 -30 10 5 17 -24 6 -11 -2 11 -18 18 -8 7 -6 080 -4 18 -6 -10 16 -2 37 -15 4 8 19 18 0 -4 -18 -12 096 22 -2 15 0 6 -5 -23 -23 17 1 12 8 9 -5 -10 20 112 5 2 13 -35 11 4 1 -3 21 -13 -3 18 23 8 -29 19 128 14 -32 21 8 18 26 -9 -15 0 -9 -39 7 -26 5 -9 -3 144 11 -11 19 -5 10 -8 -2 0 6 23 11 6 25 -7 -21 -8 160 -11 -14 12 3 -12 -22 -19 18 0 7 15 11 -15 7 4 -9 176 -25 0 -24 -21 19 -1 -7 8 -10 1 12 0 -1 2 -6 6 192 12 5 -13 12 -32 6 13 23 0 -15 14 4 0 -20 -2 -11 208 -1 -3 6 -29 2 2 -1 -18 23 -8 -30 -11 11 0 -2 -28 224 6 -3 32 -1 10 16 4 18 37 19 17 8 15 -10 13 0 240 9 7 -5 -3 19 -22 4 8 15 -17 -20 0 0 0 0 0 $ The ceilometer is vertically pointing. A measurement is made every 15 seconds. Gate spacing is 30 m. Line 1: HH:MM:SS MM/DD/YYYY Line 2: Example: 30 01230 12340 23450 FEDCBA98-J where 3 First digit of line: Status of detection as follows: 0 No significant backscatter 1 One cloud base detected 2 Two cloud bases detected 3 Three cloud bases detected 4 Full obscuration determined but no cloud base detected 5 Some obscuration detected but determined to be transparent 0 Second digit of line: Warnings and Alarm information as follows: 0 Self-check OK W At least one Warning active, no Alarms A At least one Alarm active 01230 If Detection Status is 1, 2 or 3: Lowest cloud base height If Detection Status is 4: Vertical Visibility as calculated If Detection Status is 0 or 5: ///// 12340 If Detection Status is 2 or 3: Second lowest cloud base height If Detection Status is 4: Highest signal detected If Detection Status is 0, 1 or 5: ///// 23450 If Detection Status is 3: Highest cloud base height If Detection Status is 0, 1, 2, 4, 5: ///// FEDCBA98 Alarm (A), Warning (W), and Internal Status information. Each character is a hexadecimal representation of four bits, altogether 32 bits (b00-b3 1), with the following breakdown. Interpretation as follows: F b31 Laser temperature shut-off (A) b30 Laser failure (A) b29 Receiver failure (A) b28 Voltage failure (A) E: b27 (spare) (A) b26 (spare) (A) b25 (spare) (A) b24 (spare) (A) D: b23 Window contaminated (W) b22 Battery low (W) b21 Laser power low (W) b20 Laser temperature high or low (W) C b19 Internal temperature high or low (W) b18 Voltage high or low (W) b17 Relative Humidity is > 85 % (option) (W) b16 Receiver optical cross-talk compensation poor (W) B: b15 Fan suspect (W) b14 (spare) (W) b13 (spare) (W) b12 (spare) (W) A: b11 Blower is ON b10 Blower heater is ON b09 Internal heater is ON b08 Units are METERS if ON, else FEET 9: b07 Polling mode is ON b06 Working from battery b05 Single sequence mode is ON b04 Manual settings are effective 8: b03 Tilt angle is > 45 degrees b02 (spare) b01 (spare) b00 (spare) For example, if the battery voltage is too low, a warning is given and the second line appears as 0W ///// ///// ///// 00400300 In this example the internal heater is on and units are meters. Line 3: Example: 10 0 N 53 +34 204 146 +2 621 LF7HN1 139-1 Measurement parameters are mostly in engineering units. Plus and minus signs are possible. Out-of-Range is indicated by slashes (/////). Contents: 100 Parameter SCALE, 100 (%)is normal (0 ... 999 possible) N measurement mode; N = Normal, C = Close range 53 laser pulse energy, % of nominal factory setting (0 ... 999) +34 laser temperature degrees C (-50...+99) 204 receiver sensitivity, % of nominal factory setting (0 ... 999) 146 window contamination, millivolts at internal ADC input (0 ... 2500) +2 tilt angle, degrees from vertical (-15...+90) 621 background light, millivolts at internal ADC input (0 ... 2500) LF7HN1 measurement parameters coded (pulse Long/Short, freq F, pulse qty 47+1, gain High/Low, bandwidth Narrow/NVide, sampling 10/20 MHz) 139 SUM of detected and normalized backscatter, 0 ... 999. Multiplied by scaling factor times 104. At scaling factor 100 the SUM range 0 ... 999 corresponds to integrated backscatter 0 ... 0.0999 srad-l Line 4-16: The first field is height of the first gate reported on that line divided by 100. The next 16 fields are data at successive gates. The data are range and sensitivity normalized backscatter, units (10000·srad·km)-1 Line 17: $ or blank line indicates end of record Ceilometer Description The ceilometer is a pulsed laser that operates at 0.905 um. The beamwidth is 1.06 mrad. The range is from 0 to 7.5 km, vertical resolution is 30 m and time resolution is 15 s.